Ateq D28+
  • Leak & Flow
  • Leak & Flow
  • Leak & Flow

Ateq D28+

ATEQ presents its revolutionary compact flow tester operating on the principle of direct or indirect flow measurement.

ATEQ D28+ is a Series 6 generation of flow testers with:

  • new design differential pressure transducers
  • new electronic and pneumatic modules
  • new user-friendly interface
  • new accessories and functions

The innovative technology of the Series 6 instruments was created to provide customers with industrial devices that meet the demand for quick and reliable flow testing as well as user-friendly operation.

The ATEQ D28+ flow tester head is small in size, so it can be mounted very close to the tested elements, ensuring the best possible measurement conditions.

ATEQ D28+ heads can be operated, programmed and controlled using:

  • TLC600 remote control panel,
  • WinATEQ300 software enabling the control of networks up to 255 ATEQ D28+ heads,
  • PLC controller using communication protocols (ProfiBUS, ProfiNET, EtherNET/IP, EtherCAT, ModBUS, DeviceNET)
  • Direct or indirect leak and flow measurement
  • Various flow measurement ranges: from 1 l/h to 10.000 l/h
  • Flow measurement in:
    • SI standard units
    • US units
    • custom calibrated units
  • The entire measuring system integrated in one module
  • Possibility of programming 128 test programs
  • Communication:
    • RS232: printer, barcode reader, PC computer
    • USB «master»: transfer to external USB memory (parameters, results, statistics, …)
    • USB «slave»: supervision
    • Ethernet/IP or USB «master» on the front panel or SD reader for saving results.
    • Available communication protocols: ModBus, ProfiBus, DeviceNet, ProfiNet, EtherNet/IP, EtherCAT.
  • 9 inputs / 7 outputs board – enables selection of 128 programs, test cycle START/STOP, OK/NOK result signals, etc.
  • Date and time indication, language and unit selection, ability to adapt tests to your requirements, automatic measurement cycle, …
  • 2 pneumatic outputs for automation control
  • Connections to the test item
  • Programmable 6 x 24 V outputs for external devices
  • 2 analogue outputs 0-10V or 4-20mA
  • Automatic calibration check mode
  • Tight shut-off and switching valves for construction of complex test circuits
  • Pressure and flow calibrator
  • External TLC600 remote control panel with graphic interface and high-contrast color screen

Flow testing:
gas cookers, stoves, valves, gas taps, heaters, hydrophobic water-repellent materials and membranes, catheters, dialysis devices, …

Leak detection:
valves, gearboxes, complete engines and components, …

Functional testing:
aerosol sprays, injection systems, …

FLOW MEASUREMENT
RANGE ACCURACY
1 l/h ± ( 2.5% F + 0.001 l/h )
5 l/h ± ( 2.5% F + 0.005 l/h )
30 l/h ± ( 2.5% F + 0.03 l/h )
80 l/h ± ( 2.5% F + 0.08 l/h )
150 l/h ± ( 2.5% F + 0.15 l/h )
500 l/h ± ( 2.5% F + 0.5 l/h )
1 500 l/h ± ( 2.5% F + 1.5 l/h )
4 000 l/h ± ( 2.5% F + 4 l/h )
10 000 l/h ± ( 2.5% F + 10 l/h )
*F – measured flow value
PRESSURE MEASUREMENT
RANGE ACCURACY
Pmax = 75 mbar ± ( 1.5% P + 0.2 mbar )
P < 0,3 bar ± ( 1.5% P + 1 mbar )
0,3 < P < 1 bar ± ( 1.5% P + 3 mbar )
1 < P < 5 bar ± ( 1.5% P + 7.5 mbar )
5 < P < 10 bar ± ( 1.5% P + 15 mbar )
*P – measured pressure value

MECHANICAL PRESSURE REGULATOR (EXTERNAL)
from -800 to -20 mbar • from 8 to 60 mbar • from 5 to 140 mbar • from 0,1 to 2 bar •
• from 0,4 to 4 bar • from 1 to 10 bar