Ateq DG5
  • Leak & Flow
  • Leak & Flow
  • Leak & Flow

Ateq DG5

The ATEQ DG5 system is designed for comprehensive testing of gas household appliances and enables leak detection and flow measurement in real time.
The instrument includes a leak testing module (G5), a flow measurement module (D5) and a PC interface with Sesame software developed by ATEQ.

 

  • Unlimited number of test sequences and programs.
  • Calibration using master standards.
  • Automatic test cycle start after barcode scanning.
  • System auto-test.
  • Test progress “live” visualization using graphs.
  • Automatic results saving in the computer.
  • Possibility of setting reject thresholds.
  • Automatic pressure correction.
  • Temperature correction.
  • Measurement correction to normal conditions.
  • Possibility of sending results to external label printer.
  • Possibility of using remote control panels.
  • Possibility of expanding the device’s capabilities with functional and safety tests (burner ignition, thermocouple).
  • Pneumatic outputs for automation control
  • Programmable 6 x 24 V outputs for external devices
  • 2 analogue outputs 0-10V or 4-20mA
  • Connections to the test item
  • Automatic calibration check mode
  • Electronic regulator for automatic test pressure adjustment
  • Tight shut-off and switching valves for construction of complex test circuits
  • Remote control panels
  • Barcode and 2D DataMatrix readers

Household appliances and gas industry:
leak testing and flow measurement in gas cookers, ovens, stoves, gas heaters, fittings, valves, taps, …

 

D5 FLOW MEASUREMENT MODULE:

FLOW MEASUREMENT
RANGE ACCURACY
1 l/h ± ( 2.5% F + 0.001 l/h )
5 l/h ± ( 2.5% F + 0.005 l/h )
30 l/h ± ( 2.5% F + 0.03 l/h )
80 l/h ± ( 2.5% F + 0.08 l/h )
150 l/h ± ( 2.5% F + 0.15 l/h )
500 l/h ± ( 2.5% F + 0.5 l/h )
1 500 l/h ± ( 2.5% F + 1.5 l/h )
4 000 l/h ± ( 2.5% F + 4 l/h )
10 000 l/h ± ( 2.5% F + 10 l/h )
*F – measured flow value
PRESSURE MEASUREMENT
RANGE ACCURACY
Pmax = 75 mbar ± ( 1.5% P + 0.2 mbar )
P < 0,3 bar ± ( 1.5% P + 1 mbar )
0,3 < P < 1 bar ± ( 1.5% P + 3 mbar )
1 < P < 5 bar ± ( 1.5% P + 7.5 mbar )
5 < P < 10 bar ± ( 1.5% P + 15 mbar )
*P – measured pressure value

MECHANICAL PRESSURE REGULATOR
from -800 to -20 mbar • from 8 to 60 mbar • from 5 to 140 mbar • from 0,1 to 2 bar •
• from 0,4 to 4 bar • from 1 to 10 bar

ELECTRONIC PRESSURE REGULATOR
from 10 to 200 mbar • from 20 to 500 mbar • from 0.2 to 2 bar •
• from 0.5 to 5 bar • from 1 to 10 bar

 

G5 LEAK MEASUREMENT MODULE:

LEAK MEASUREMENT
RANGE ACCURACY MAX RESOLUTION
100 ml/h ± ( 3.5% F + 0.5 ml/h ) 0.1 ml/h
1000 ml/h ± ( 3.5% F + 5 ml/h ) 1 ml/h
*F – measured leak value
PRESSURE MEASUREMENT
RANGE ACCURACY
1 bar ± ( 1.5% P + 3 mbar )
5 bar ± ( 1.5% P + 7.5 mbar )
*P – measured pressure value

MECHANICAL PRESSURE REGULATOR
from 50 to 1000 mbar • from 0,5 to 4 bar